Required Accessory Off-street Loading Berths
C1 C2 C3 C4 C5 C6 C7 C8
In all districts, as indicated, accessory off-street loading berths, open or enclosed, shall be provided in conformity with the requirements set forth in the table in this Section and under rules and regulations promulgated by the Commissioner of Buildings, for all developments or enlargements after December 15, 1961, for the uses listed in the table, except as otherwise provided in Section 36-63 (Special Provisions for a Single Zoning Lot With Uses Subject to Different Loading Requirements) or 36-64 (Wholesale, Manufacturing or Storage Uses Combined With Other Uses), as a condition precedent to the use of such development or enlargement.
After December 15, 1961, if the use of any building or other structure or zoning lot is changed or enlarged, the requirements set forth in the table shall apply to the floor area of the changed or enlarged portion of such building or of the lot area used for such use.
For the purposes of this Section, a tract of land on which a group of such uses is developed under single ownership or control shall be considered a single zoning lot.
Whenever any use specified in the table is located on an open lot, the requirements set forth in the table for floor area shall apply to the lot area used for such use.
REQUIRED OFF-STREET LOADING BERTHS FOR DEVELOPMENTS, ENLARGEMENTS OR CHANGES OF USE
District |
Type of Use |
For Floor Area |
Required Berths |
C1 C2 C3 C4 C5 C6 C8 |
Hospitals and related facilities1 or prisons |
First 10,000 sq. ft. Next 290,000 sq. ft. Each additional 300,000 sq. ft. or fraction thereof |
None 1 1 |
C1 C2 C4 C6 C8 |
Funeral establishments |
First 10,000 sq. ft. Next 20,000 sq. ft. Any additional amount |
1 1 1 |
C12 C22 C3 C4-1 C4-2 C4-3 C8-1 C8-2 |
Hotels, offices or court houses |
First 25,000 sq. ft. Next 75,000 sq. ft. Next 200,000 sq. ft. Each additional 300,000 sq. ft. or fraction thereof |
None 1 1 1 |
C13 C1-6 C1-7 C1-8 C1-9 C23 C2-6 C2-7 C2-8 C4-4 C4-5 C4-6 C4-7 C5 C6 C8-3 C8-4 |
Hotels, offices or court houses |
First 100,000 sq. ft. Next 200,000 sq. ft. Each additional 300,000 sq. ft. or fraction thereof |
None 1 1 |
C12 C22 C3 C4-1 C4-2 C4-3 C7 C8-1 C8-2 |
commercial uses All retail or service uses listed in Use Group 6A, 6C, 7B, 8B, 9A, 9B, 10A, 12B, 14A or 16A All amusement uses listed in Use Group 8A or 12A All automotive service uses listed in Use Group 7D |
First 8,000 sq. ft. Next 17,000 sq. ft. Next 15,000 sq. ft. of floor area Next 20,000 sq. ft. Next 40,000 sq. ft. Each additional 150,000 sq. ft. or fraction thereof |
None 1 1 1 1 1 |
C13 C1-6 C1-7 C1-8 C1-9 C23 C2-6 C2-7 C2-8 C4-4 C4-5 C4-6 C4-7 C5 C6 C8-3 C8-4 |
commercial uses All retail or service uses listed in Use Group 6A, 6C, 7B, 8B, 9A, 9B, 10A, 12B, 14A or 16A All amusement uses listed in Use Group 8A or 12A All automotive service uses listed in Use Group 7D |
First 25,000 sq. ft. Next 15,000 sq. ft. Next 60,000 sq. ft. Each additional 150,000 sq. ft. or fraction thereof |
None 1 1 1 |
C22 C4-1 C4-2 C4-3 C8-1 C8-2 |
Service, wholesale, manufacturing, or storage uses All service, wholesale or storage uses listed in Use Group 7C, 10B, 11B, or 16D All manufacturing uses listed in Use Group 11A |
First 8,000 sq. ft. Next 17,000 sq. ft. Next 15,000 sq. ft. Next 20,000 sq. ft. Next 20,000 sq. ft. Each additional 80,000 sq. ft. or fraction thereof |
None 1 1 1 1 1 |
C23 C2-6 C2-7 C2-8 C4-4 C4-5 C4-6 C4-7 C5 C6 C8-3 C8-4 |
Service, wholesale, manufacturing, or storage uses All service, wholesale or storage uses listed in Use Group 7C, 10B, 11B, or 16D All manufacturing uses listed in Use Group 11A
|
First 15,000 sq. ft. Next 25,000 sq. ft. Next 40,000 sq. ft. Each additional 80,000 sq. ft. or fraction thereof |
None 1 1 1 |
1 Requirements in this table are in addition to area utilized for ambulance parking
2 Mapped within R1, R2, R3, R4, R5, R6
3 Mapped within R7, R8, R9, R10