36-62

Required Accessory Off-street Loading Berths

C1 C2 C3 C4 C5 C6 C7 C8

In all districts, as indicated, accessory off-street loading berths, open or enclosed, shall be provided in conformity with the requirements set forth in the table in this Section and under rules and regulations promulgated by the Commissioner of Buildings, for all developments or enlargements after December 15, 1961, for the uses listed in the table, except as otherwise provided in Section 36-63 (Special Provisions for a Single Zoning Lot With Uses Subject to Different Loading Requirements) or 36-64 (Wholesale, Manufacturing or Storage Uses Combined With Other Uses), as a condition precedent to the use of such development or enlargement.

 

After December 15, 1961, if the use of any building or other structure or zoning lot is changed or enlarged, the requirements set forth in the table shall apply to the floor area of the changed or enlarged portion of such building or of the lot area used for such use.

 

For the purposes of this Section, a tract of land on which a group of such uses is developed under single ownership or control shall be considered a single zoning lot.

 

Whenever any use specified in the table is located on an open lot, the requirements set forth in the table for floor area shall apply to the lot area used for such use.

REQUIRED OFF-STREET LOADING BERTHS FOR DEVELOPMENTS, ENLARGEMENTS OR CHANGES OF USE

District

Type of Use

For Floor Area

Required Berths

C1 C2 C3 C4 C5 C6 C8

Hospitals and related facilities1 or prisons

First 10,000 sq. ft.

Next 290,000 sq. ft.

Each additional 300,000 sq. ft. or fraction thereof

None

1

1

C1 C2 C4 C6 C8

Funeral establishments

First 10,000 sq. ft.

Next 20,000 sq. ft.

Any additional amount

1

1

1

C12 C22 C3 C4-1 C4-2 C4-3 C8-1 C8-2

Hotels, offices or court houses

First 25,000 sq. ft.

Next 75,000 sq. ft.

Next 200,000 sq. ft.

Each additional 300,000 sq. ft. or fraction thereof

None

1

1

1

C13 C1-6 C1-7 C1-8 C1-9 C23 C2-6 C2-7 C2-8 C4-4 C4-5 C4-6 C4-7 C5 C6 C8-3 C8-4

Hotels, offices or court houses

First 100,000 sq. ft.

Next 200,000 sq. ft.

Each additional 300,000 sq. ft. or fraction thereof

None

1

1

C12 C22 C3 C4-1 C4-2 C4-3 C7 C8-1 C8-2

commercial uses

All retail or service uses listed in Use Group 6A, 6C, 7B, 8B, 9A, 9B, 10A, 12B, 14A or 16A

All amusement uses listed in Use Group 8A or 12A

All automotive service uses listed in Use Group 7D

First 8,000 sq. ft.

Next 17,000 sq. ft.

Next 15,000 sq. ft. of floor area

Next 20,000 sq. ft.

Next 40,000 sq. ft.

Each additional 150,000 sq. ft. or fraction thereof

None

1

1

1

1

1

C13 C1-6 C1-7 C1-8 C1-9 C23 C2-6 C2-7 C2-8 C4-4 C4-5 C4-6 C4-7 C5 C6 C8-3 C8-4

commercial uses

All retail or service uses listed in Use Group 6A, 6C, 7B, 8B, 9A, 9B, 10A, 12B, 14A or 16A

All amusement uses listed in Use Group 8A or 12A

All automotive service uses listed in Use Group 7D

First 25,000 sq. ft.

Next 15,000 sq. ft.

Next 60,000 sq. ft.

Each additional 150,000 sq. ft. or fraction thereof

None

1

1

1

C22 C4-1 C4-2 C4-3 C8-1 C8-2

Service, wholesale, manufacturing, or storage uses

All service, wholesale or storage uses listed in Use Group 7C, 10B, 11B, or 16D

All manufacturing uses listed in Use Group 11A

First 8,000 sq. ft.

Next 17,000 sq. ft.

Next 15,000 sq. ft.

Next 20,000 sq. ft.

Next 20,000 sq. ft.

Each additional 80,000 sq. ft. or fraction thereof

None

1

1

1

1

1

C23 C2-6 C2-7 C2-8 C4-4 C4-5 C4-6 C4-7 C5 C6 C8-3 C8-4

Service, wholesale, manufacturing, or storage uses

All service, wholesale or storage uses listed in Use Group 7C, 10B, 11B, or 16D

All manufacturing uses listed in Use Group 11A

 

First 15,000 sq. ft.

Next 25,000 sq. ft.

Next 40,000 sq. ft.

Each additional 80,000 sq. ft. or fraction thereof

None

1

1

1

1        Requirements in this table are in addition to area utilized for ambulance parking

 

2        Mapped within R1, R2, R3, R4, R5, R6

3        Mapped within R7, R8, R9, R10

Top