36-661
Size of required berths
C1 C2 C3 C4 C5 C6 C7 C8
In all districts, as indicated, all required accessory off- street loading berths, open or enclosed, shall conform to the regulations on minimum dimensions set forth in the following table. The dimensions of off-street berths shall not include driveways or entrances to or exits from such off-street berths. Loading requirement categories (LRC) shall be as set forth in Section 36-62 (Required Accessory Off-street Loading Berths).
MINIMUM DIMENSIONS FOR REQUIRED
ACCESSORY OFF-STREET LOADING BERTHS (in feet)
Length |
Width |
Vertical |
||
LRC-A |
with less than 10,000 sq. ft. of floor area |
37 |
12 |
14 |
with 10,000 sq. ft. or more of floor area |
50 |
12 |
14 |
|
LRC-B |
37 |
12 |
14 |
|
LRC-C |
37 |
12 |
12 |
|
LRC-D |
37 |
12 |
12 |
|
LRC-E |
25 |
10 |
8 |