127-411

Special provisions for frontages along streets and the shoreline

The provisions of this Section shall apply to developments or ground floor level enlargements.

(a)        At the intersection of primary street frontages

For ground floor level street walls within 50 feet of the intersection of two primary street frontages, as shown on Map 3 in the Appendix to this Chapter:

(1)        uses on the ground floor level, to the minimum depth set forth in Section 37-32 (Ground Floor Depth Requirements for Certain Uses), shall be limited to non-residential uses, except for lobbies.

(2)        Group parking facilities located on the ground floor level of a building shall be wrapped by floor area in accordance with the provisions of paragraph (a) of Section 37-35 (Parking Wrap and Screening Requirements), and above the ground floor level, such parking facilities shall be wrapped by floor area or screened in accordance with the provisions of Section 37-35.

(3)        Ground floor level street walls shall be glazed in accordance with the provisions set forth in Section 37-34 (Minimum Transparency Requirements).

(b)        Along other street frontages

For portions of buildings along the remainder of primary street frontages, and for buildings with secondary street frontages, as shown on Map 3, group parking facilities located on the ground floor level shall be wrapped by floor area or screened in accordance with the provisions of Section 37-35. However, for portions of buildings facing the shoreline, group parking facilities at all levels shall be wrapped by floor area or screened in accordance with the provisions of Section 37-35.

Top