Size of required berths
C1 C2 C3 C4 C5 C6 C7 C8
In all districts, as indicated, all required accessory off- street loading berths, open or enclosed, shall conform to the regulations on minimum dimensions set forth in the following table. The dimensions of off-street berths shall not include driveways or entrances to or exits from such off-street berths.
MINIMUM DIMENSIONS FOR REQUIRED ACCESSORY OFF-STREET LOADING BERTHS
(in feet)
Length | Width | Vertical Clearance | ||
commercial uses* | 33 | 12 | 14 | |
Funeral establishments | 25 | 10 | 8 | |
Hospitals and related facilities or prisons | 33 | 12 | 12 | |
Hotels, offices or court houses | 33 | 12 | 12 | |
Wholesale, manufacturing or storage uses: | with less than 10,000 sq. ft. of floor area | 33 | 12 | 14 |
with 10,000 sq. ft. or more of floor area | 50 | 12 | 14 |
* As set forth in the table in Section 36-62 (Required Accessory Off-street Loading Berths)