36-62

Required Accessory Off-street Loading Berths

C1 C2 C3 C4 C5 C6 C7 C8

In all districts, as indicated, accessory off-street loading berths, open or enclosed, shall be provided in conformity with the requirements set forth in the table in this Section and under rules and regulations promulgated by the Commissioner of Buildings, for all developments or enlargements after December 15, 1961, for the uses listed in the table, as a condition precedent to the use of such development or enlargement.

For the purposes of this Section, a tract of land on which a group of such uses is developed under single ownership or control shall be considered a single zoning lot.

Whenever any use specified in the table is located on an open lot, the requirements set forth in the table for floor area shall apply to the lot area used for such use.

For the purposes of applying the loading requirements of this Chapter, uses are grouped into the following Loading Requirement Categories (LRC).

        

Loading Requirement Category

Use or Use Group

LRC – A

All uses listed under Use Groups IX(A), IX(B) and X

LRC – B

All uses listed under Use Group VI, except automotive equipment rental and leasing, automotive repair and maintenance, or gasoline stations; all uses listed under Use Group VIII

LRC – C

All uses listed under Use Groups V and VII; court houses listed under Use Group IV(A)

LRC – D

Hospitals and related facilities listed under Use Group III(B); prisons listed under Use Group IV(A)

LRC – E

Funeral establishments listed under Use Group VI

        

REQUIRED OFF-STREET LOADING BERTHS FOR 
DEVELOPMENTS OR ENLARGEMENTS

Loading Requirement Category

Districts

C12 C22 C3

C4-1 C4-2 C4-3

C8-1 C8-2

C7 outside the expanded transit zone

C13 C1-6 C1-7 C1-8 C1-9 C23 C2-6 C2-7 C2-8

C4-4 C4-5 C4-6 C4-7 C5 C6

C8-3 C8-4

C7 within the expanded transit zone

LRC-A

First 8,000 sq. ft.: None
Next 17,000 sq. ft.: 1
Next 15,000 sq. ft.: 1
Next 20,000 sq. ft.: 1
Next 20,000 sq. ft.: 1
Each additional 80,000 sq. ft.: 1

First 15,000 sq. ft.: None
Next 25,000 sq. ft.: 1
Next 40,000 sq. ft.: 1
Each additional 80,000 sq. ft.: 1

LRC-B

First 8,000 sq. ft.: None
Next 17,000 sq. ft.: 1
Next 15,000 sq. ft.: 1
Next 20,000 sq. ft.: 1
Next 40,000 sq. ft.: 1
Each additional 150,000 sq. ft.: 1

First 25,000 sq. ft.: None
Next 15,000 sq. ft.: 1
Next 60,000 sq. ft.: 1
Each additional 150,000 sq. ft.: 1

LRC-C

First 25,000 sq. ft.: None
Next 75,000 sq. ft.: 1
Next 200,000 sq. ft.: 1
Each additional 300,000 sq. ft.: 1

First 100,000 sq. ft.: None
Next 200,000 sq. ft.: 1
Each additional 300,000 sq. ft.: 1

LRC-D 1

First 10,000 sq. ft.: None
Next 290,000 sq. ft.: 1
Each additional 300,000 sq. ft.: 1

LRC E

First 10,000 sq. ft.: None
Next 20,000 sq. ft.: 1
Any additional amount : 1

1              Requirements in this table are in addition to area  utilized for ambulance parking.

2              Mapped within R1, R2, R3, R4, R5, R6.

3              Mapped within R7, R8, R9, R10.

Top