36-681

Size of required berths

C1 C2 C3 C4 C5 C6 C7 C8

In all districts, as indicated, all required accessory off- street loading berths, open or enclosed, shall conform to the regulations on minimum dimensions set forth in the following table. The dimensions of off-street berths shall not include driveways or entrances to or exits from such off-street berths.

MINIMUM DIMENSIONS FOR REQUIRED ACCESSORY OFF-STREET LOADING BERTHS

(in feet)

Length

Width

Vertical Clearance

commercial uses*

33

12

14

Funeral establishments

25

10

8

Hospitals and related facilities or prisons

33

12

12

Hotels, offices or court houses

33

12

12

Wholesale, manufacturing or storage uses:

with less than 10,000 sq. ft. of floor area

33

12

14

with 10,000 sq. ft. or more of floor area

50

12

14

*        As set forth in the table in Section 36-62 (Required Accessory Off-street Loading Berths)

Top