44-581

Size of required loading berths

M1 M2 M3

In all districts, as indicated, all required off-street loading berths, open or enclosed, shall conform to the regulations on minimum dimensions set forth in the following table. The dimensions of off-street berths shall not include driveways, or entrances to or exits from such off-street berths.

MINIMUM DIMENSIONS FOR REQUIRED ACCESSORY OFF-STREET LOADING BERTHS (in feet)

Length

Width

Vertical Clearance

Hospitals and related facilities or prisons

33

12

12

Funeral establishments

25

10

8

Hotels, offices or court houses

33

12

12

Commercial uses*

33

12

14

Wholesale, manu-facturing or storage uses :

with less than 10,000 square feet of floor area

33

12

14

with 10,000 square feet of floor area or more

50

12

14

*        As set forth in the table in Section 44-52 (Required Accessory Off-street Loading Berths)